HB-HS864 Composite Insulator Hydrophobicity Laboratory Evaluation System
1. Smart Automation Testing: Integrates inspection, spraying water, photography, and grading into a full process, completing the test without manual intervention.
2. Precise Standardized Testing: Strictly follows the spray water grading method and DL/T864-2004 industry standards, with precise control over spray volume and angle.
3. Multi-dimensional Intelligent Analysis: Based on machine vision and digital image processing technology, extracts image data to achieve objective determination of hydrophobicity grade.
4. Full-process Visual Monitoring: Dedicated cameras are installed in the testing area, providing stable environmental guarantees for the detection process.
Composite Insulator Hydrophobicity Laboratory Evaluation System, through manual single piece or automatic whole string test mode, can accurately detect the hydrophobicity of composite insulators in the laboratory environment, helping to understand the insulator's pollution flashover resistance capability, and providing support for maintenance of insulators in power systems and prevention of accidents.
Specifications
- Scope of Application
- Composite insulator structure height ≤1500mm; Porcelain, glass (RTV) insulators: disc diameter ≤450mm;
- Test Method
- Manual single piece, automatic whole string
- Water quantity per spray
- 0.7-1.0ml
- Number of spray cycles per time
- 25 times
- Test Time
- Within 30s after spraying is completed
- Hydrophobicity grade classification error
- ±1 grade
- Hydrophobicity grade classification
- Spray water grading method (i.e., HC method)
- Hydrophobicity Grade Analysis Software
- Insulator Hydrophobicity Detection and Evaluation System
- Camera
- 5MP industrial-grade camera, which can control the lens aperture and focus adjustment through the analysis software.
- Control Method
- Switchable between manual and automatic
- Insulator Scanning Method
- High-precision CMOS-type laser distance measurement module with automatic compensation function for measurement reference
- Laser
- Maximum power 1mW, peak wavelength 655nm
- Linearity
- ±0.2%F.S
- Repeatability
- 300μm
- Response Time
- 1ms
- Laser Scanning Auxiliary Motor
- High-precision stepper motor, maximum resolution 6000 pulses/revolution
- Insulator Position Adjustment Auxiliary Motor
- High-precision stepper motor, maximum resolution 4000 pulses/revolution
- Ambient Temperature
- 0~40℃
- Ambient Humidity
- ≤80%RH
- Test Cabinet
- 1026*803*2103 (mm)
- Control Panel
- 600*900*750 (mm)